Thermochemistry
FREN

MODULE 3 / 6

Enthalpy

Understand the enthalpy function and changes associated with heating and phase transitions.

The enthalpy function

Many physical or chemical processes occur at atmospheric pressure, treated as constant, particularly when the medium is in contact with open air. To study their energy balance, it is useful to define a suitable thermodynamic potential: enthalpy.

We consider a closed system: an open-air process can be modelled this way if matter exchange with the surroundings is negligible. The imposed external pressure does not prevent volume changes by expansion or compression.

Enthalpy

Thermodynamic potential

Enthalpy is the state function defined by:

H=U+pV

It combines internal energy U with the term pV, where p is the system pressure. This term accounts for pressure–volume work in a constant-pressure balance; pV is not itself the work exchanged.

Why does the enthalpy change give the heat at constant pressure?

The system is closed, only pressure–volume work is exchanged, and changes in macroscopic kinetic and potential energies are negligible. External pressure is constant and the initial and final states are in mechanical equilibrium with the surroundings:

pi=pf=pext

The work received, positive for compression and negative for expansion, is:

W=−pext(Vf−Vi)

The first law then gives:

ΔU=Qp−pextΔV

By definition of H, since the initial and final pressures equal the external pressure:

ΔH=ΔU+Δ(pV)=ΔU+pextΔV

Substituting ΔU, the two pressure–volume work terms cancel:

ΔH=Qp−pextΔV+pextΔV=Qp

Interpreting the sign of ΔH

Under these conditions, the enthalpy change equals the heat exchanged at constant pressure. An exothermic process releases heat: ΔH < 0. An endothermic process receives heat: ΔH > 0.

This relationship applies at atmospheric pressure or any other constant external pressure if the same conditions hold. H is a state function; its change ΔH corresponds to the heat exchanged in this balance.

What does ΔH mean?

H is enthalpy, the state function defined by H = U + pV. Δ denotes its change between two states : ΔH = Hf − Hᵢ. Under the conditions stated above, this change is the heat transferred.

The notations ΔrH°T, ΔfH°T or ΔvapH°T then specify the process type, standard states and temperature. Each symbol is explained in the “Reaction enthalpy” module.

Heat capacity

Heat capacity C

Heat required to raise a constituent's temperature by 1 °C (or 1 K). It is expressed in J·K⁻¹.

δQ = C dT ; Q = C ΔT

These relationships describe heating without reaction or phase transition under specified conditions. Q = C ΔT assumes constant C over the interval. At constant pressure, use Cp.

Capacity Unit Calculation
C J·K⁻¹ Q = C ΔT
Molar Cp,m J·mol⁻¹·K⁻¹ Q = n Cp,m ΔT
Specific cp J·kg⁻¹·K⁻¹ or J·g⁻¹·K⁻¹ Q = m cp ΔT

For several constituents, add their contributions. The mass or amount of substance must match the unit of the given capacity.

Enthalpy change with temperature

At constant pressure, for a fixed amount of a constituent undergoing no reaction or phase transition:

dH = Cp dT ; Cp = (∂H/∂T)p

We may write Cp(T) = a + bT + cT². Heat capacity is often treated as constant over the interval:

ΔH = Qp = ∑ᵢ nᵢ Cp,m,i ΔT

If temperature dependence is included, integrate Cp(T). Useful antiderivatives are listed in the practical reference.

Heating and phase transitions

Melting and vaporisation require energy to overcome the cohesive forces of condensed phases. Temperature remains constant during a pure substance's phase transition at constant pressure.

Qmelting = n ΔfusH°
Qvaporisation = n ΔvapH°

Understanding latent heat

During melting or vaporisation of a pure substance at constant pressure, the system receives energy while its temperature stays constant: this energy enables the phase transition. The plateau below illustrates this situation. The term latent heat denotes this phase-transition heat; “latent” indicates that the supplied heat does not cause a temperature increase here.

Distinguish the total heat exchanged from the quantity specified per unit amount:

QuantityUnitMeaning
QpJ or kJHeat exchanged by the entire amount undergoing the phase transition.
ΔfusH or ΔvapHJ·mol⁻¹ or kJ·mol⁻¹Phase-transition enthalpy for one mole.
Lfus or LvapJ·kg⁻¹ or J·g⁻¹Specific latent heat, per kilogram or gram.
Qp = n Δphase transitionH = m L
L = Δphase transitionH / M

M is molar mass: with molar ΔH in J·mol⁻¹ and M in kg·mol⁻¹, L is in J·kg⁻¹. In these expressions, n or m is the amount actually transformed, at the phase-transition temperature.

For melting and vaporisation, L is positive and the system receives heat. At the same temperature, the reverse processes release this heat: Qfreezing = −m Lfus and Qcondensation = −m Lvap.

Example: Vaporising the 3 mol of water already at 100 °C requires 3 × 40.7 = 122.1 kJ. The preceding heating from 20 to 100 °C is calculated separately. Use m c ΔT for heating within one phase and m L for the phase transition: ΔT = 0 on the plateau does not mean Q = 0.

Data: references and notes (water)

EXPLORE THE EXAMPLE

From water to vapour: where does the received heat go?

Heat is supplied to 3 mol of liquid water at 20 °C, at constant pressure (boiling at 100 °C in this model), until vapour at 100 °C is obtained. Data: Cp,m = 75.3 J·mol⁻¹·K⁻¹, assumed constant, and ΔvapH° = 40.7 kJ·mol⁻¹. Heat losses to the surroundings are neglected.

Data: references and notes (water)

Temperature versus total heat receivedTemperature rises from 20 to 100 degrees over 18.072 kilojoules, then stays at 100 degrees until 140.172 kilojoules. T (°C)20100018.1140.2Total heat received Q (kJ)Vaporisation plateau

Total heat
0.000 kJ

Temperature
20.00 °C

State of water
Liquid

● Liquid: 3.000 mol● Vapour: 0.000 mol

The coloured lengths represent amounts of substance, not occupied volumes.

Follow the calculation at this step

Before the plateau, heat received increases the liquid's temperature.

The horizontal axis represents energy, not time. The animation does not represent an actual heating rate. At the end of the plateau, all water has vaporised; subsequent vapour heating is not shown.

Splitting heating into several steps

When the initial and final states span several phases, split the path at each phase transition. At the pressure considered, with melting at 0 °C and boiling at 100 °C, going from ice at Tᵢ < 0 °C to vapour at Tf > 100 °C requires five contributions:

  1. Heat the ice: Q₁ = m cice(0 − Tᵢ).
  2. Melt the ice: Q₂ = n ΔfusH.
  3. Heat liquid water: Q₃ = m cwater(100 − 0).
  4. Vaporise water: Q₄ = n ΔvapH.
  5. Heat the vapour: Q₅ = m cvapour(Tf − 100).
Qtotal = Q₁ + Q₂ + Q₃ + Q₄ + Q₅

Use the heat capacity of the phase present and the phase-transition enthalpy at the step's temperature. Reversing a phase transition changes the enthalpy sign: condensation releases the heat absorbed by vaporisation at the same temperature.

HEATING IN FIVE STEPS

Heating a pure substance: from solid to vapour

We heat 3 mol of water, from ice at −10 °C to vapour at 120 °C, at constant pressure, with melting at 0 °C and vaporisation at 100 °C. Follow the temperature in kelvins over time : it increases within a single phase and stays constant during each phase transition.

Solid heating, melting, liquid heating, vaporisation and vapour heating Five successive segments: rise, solid–liquid plateau, rise, liquid–vapour plateau, rise. The axes are qualitative, without numerical values. T (K)Time TfusTvap SS + LLL + VV

S: solid; L: liquid; V: vapour. The plateaux correspond to S + L and then L + V coexistence.

Temperature

Total heat received

Total amount
3 mol of water

Numerical calculation along the curve
Data used in this complete example

Cₚ,ₘ(ice) = 37.62 and Cₚ,ₘ(vapour) = 33.58 J·mol⁻¹·K⁻¹; ΔfusH = 6.00 kJ·mol⁻¹. Cₚ,ₘ(liquid) = 75.3 J·mol⁻¹·K⁻¹ and ΔvapH = 40.7 kJ·mol⁻¹ are retained.

Data: references and notes (water)

Check my understanding with the quiz

Visitor statistics

Simple Analytics counts visits to the public Thermochemistry site without cookies. Quiz and exercise answers and scores are stored in your browser; they are not sent to this analytics service.

Terms of use and citation

Your progress

This site is freely accessible. Results are stored only in your browser and are not sent to your lecturer. Page views are measured with Simple Analytics, without student accounts or transmission of answers or scores. According to the provider, this measurement does not use cookies or retain IP addresses. Exercise answers and quiz history remain in this browser. Embedded discussions use GitHub and giscus; messages you post are public.